AED Plus Battery Replacement Ensuring Emergency Readiness

February 15, 2026

En son şirket Blog yazısı AED Plus Battery Replacement Ensuring Emergency Readiness
AED Plus Battery Replacement Guide

When cardiac arrest strikes, every second counts. Is your AED Plus fully prepared to spring into action at a moment's notice? The battery serves as the power source for your automated external defibrillator—much like ammunition for a soldier. To ensure your AED Plus functions reliably during critical moments, regular battery replacement is paramount. This comprehensive guide details the preparation and precautions for replacing your AED Plus batteries.

The Vital Core: Why Regular AED Plus Battery Replacement Matters

Imagine facing a life-threatening emergency, only to discover your AED fails to function due to depleted batteries. This nightmare scenario can be prevented through proper maintenance. The AED Plus operates on 10 CR123A lithium batteries, whose performance directly impacts the device's life-saving capabilities. Regular replacement ensures your defibrillator remains in optimal working condition.

Replacement Timeline: Identifying the Critical Window
  • Standard replacement: The AED Plus requires new batteries after 3 years of installation, while the AED Plus WS model needs replacement after 5 years.
  • Alert notifications: Immediately replace batteries when the device displays a replacement warning.
  • Exceptional circumstances: Battery lifespan varies with environmental temperature and usage frequency. Heed any early low-battery alerts without delay.
Preparation: Ensuring a Smooth Replacement Process

Proper preparation streamlines the battery replacement process and prevents unnecessary complications.

Required Tools:
  • 10 new CR123A lithium batteries (Duracell brand recommended)
  • A ¥10 coin or flathead screwdriver of similar size
Locating Backup Batteries:
  • Most AED Plus units store backup batteries in the side pocket of the host device's soft case
  • Note: The AED Plus WS model doesn't include backup batteries and requires separate purchase
Step-by-Step Replacement Procedure

Follow these instructions precisely to maintain your AED Plus's operational readiness:

  1. Access the battery compartment: Using the coin or screwdriver, open the compartment following the device manual's instructions.
  2. Remove expired batteries: Extract all 10 depleted batteries.
  3. Install fresh batteries: Insert 10 new CR123A lithium batteries, observing proper polarity alignment.
  4. Secure the compartment: Ensure complete closure and locking of the battery cover.
Critical Replacement Considerations

Observe these precautions during battery replacement to guarantee proper AED function:

Battery Specifications:
  • Use only CR123A lithium batteries—preferably Duracell brand—for optimal performance
  • Never substitute other battery types, as they may damage the device
Expiration Dates:
  • Verify battery expiration dates printed on packaging
  • Expired batteries exhibit reduced performance and compromise AED functionality
Battery Consistency:
  • Never mix old and new batteries—voltage and capacity differences may cause malfunction
  • Avoid reinserting previously used batteries
Complete Replacement:
  • Replace all 10 batteries simultaneously—partial replacement isn't detectable by the device
Self-Test Protocol:
  • After installation, the AED Plus automatically initiates a self-diagnostic check
  • Confirm proper operation through the status indicator (typically a green checkmark)
Reset Button:
  • Press the reset button only after installing all 10 new batteries
  • Complete this step within 15 seconds to prevent the device from misidentifying the batteries
  • Failure to reset prompts the device to recognize the new batteries as previously installed ones
Proper Disposal of Used Batteries

Batteries contain hazardous materials requiring responsible disposal to prevent environmental contamination.

Recycling:
  • Deposit used batteries in designated recycling bins available at many communities, supermarkets, and electronics retailers
  • Never discard batteries indiscriminately
Safety Precautions:
  • Insulate battery terminals with tape before disposal to prevent short-circuiting
  • Avoid crushing, impacting, or disassembling used batteries
Routine AED Plus Maintenance

Beyond battery replacement, regular upkeep ensures your defibrillator remains emergency-ready.

Periodic Inspection:
  • Regularly verify the status indicator displays normal operation
  • Inspect electrode pads for integrity and sufficient conductive gel
Cleaning:
  • Wipe the exterior with a clean, damp cloth
  • Avoid alcohol-based or corrosive cleaning solutions
Storage:
  • Keep the device in a cool, dry, ventilated area away from direct sunlight and moisture
  • Ensure easy accessibility for emergency situations

Maintaining your AED Plus through proper battery replacement and routine care represents both a commitment to preserving life and fulfillment of civic responsibility. Keep your life-saving equipment in peak condition, ready to serve when seconds matter most.